Temperature Sensitive Paints 

UniTemp Temperature Sensitive Paint 

(Product ID: UNT-12, UNT-XXX)

      UniTemp is a single-luminophore, single application temperature sensitive paint.  The TSP may be applied to most surfaces, but a screen layer such as SCR or FB is recommended for plastics and rapid prototyping resins to protect the surface from solvent damage.  A desirable feature of UniTemp is ease of application.  Simply shake the can and spray the surface.  The result is a single coat application paint that may be applied directly to most materials.  UniTemp is an effective quantitative TSP.  It is also effective in compensating for errors due to model displacement and deformation.  UniTemp is recommended for both advanced TSP users who seek quantitative data and users who seek to gain experience with temperature sensitive paints.

Specifications

Pressure sensitivity 0% per kPa
Pressure range N/A
Temperature sensitivity 0.9% per °C
Temperature range 10°C to 80°C
Response time 750-ms
Excitation 380-nm to 520-nm (Peak: 460-nm)
Emission 500-nm to 720-nm
Photo-degradation rate 1% per hour
Shelf life 12-months
Filter 550-nm
Excitation Light Source 460-nm

 UniTemp

 


Downloads

Painting instructions: PDF

Data sheet: PDF

SDS - Aerosol Can: PDF

SDS - Jar: PDF

Calibration (PCO.1600, 460-nm LED): UniTemp

Calibration (PSP-CCD-M, 400-nm LED): UniTemp

Calibration (PSP-CCD-M, 460-nm LED): UniTemp


Available quantities: 200-ml, 400-ml, 750-ml

Surface coverage is approximately 1 square meter  per liter. 

UNT application

Heat Transfer measurements on the impingement surface of and underexpanded sonic jet impinging at an inclined angle using Temperature Sensitive Paint.

 

UniTemp

Calibration of UniTemp TSP

 

UNT Spectra

Emission spectra of UNT TSP.  Excited using LM2X-DM-460 LED

 


CCTR TSP

(Product ID: CCTR-XXX)

Specifications

Pressure Sensitivity: 0% per kPa

Temperature Sensitivity: 1.8% per °C

Excitation (CCTR): 460-nm

Emission (CCTR): 610-nm peak

CCTR

 


Downloads

Data Sheet: PDF

Painting Intructions: PDF

CCTR SDS: PDF


Available quantities: 200-ml, 400-ml, 750-ml

Surface coverage is approximately 1 square meter  per liter. 

CCTR Calibration

Calibration of CCTR TSP

CCTR

Emission spectra of a CCTR TSP.  Excited using LM2X-DM-460 LED

 

 


CCTE TSP

(Product ID: CCTR-XXX)

Specifications

Pressure Sensitivity: 0% per kPa

Temperature Sensitivity: 

Excitation (CCTE): 400-nm

Emission (CCTE): 610-nm peak

CCTE


Downloads

Painting Intructions: PDF

CCTE SDS: PDF


Available quantities: 200-ml, 400-ml, 750-ml

Surface coverage is approximately 1 square meter  per liter. 

 

For ordering information, please contact our sales department: issi-sales@innssi.com or call us at (937) 630-3012